- 微生物專用設備
- 細胞專用設備
- 基礎理化設備
- 溶液處理移液設備
- 蛋白質專用設備
- Cellpro
- 試劑類
- 培養基類
- 實驗室耗材類
- 儀器維修&校正服務
- 防疫專區
- infitek系列
- pakgent系列
- 塑膠耗材類別
- 冷藏冰箱
-
商品資訊
Description
ULF86-H110 ULF86-H490 Features
1.Wide available voltage range: 187V~242V.
2.Wide temperature range :10℃~32℃ambinet temperature can reach -86℃.
3.Accurate Temperature control technology to make the temperature maintain -86℃~-40℃.
4.304 stainless steel inner chamber for friendly using and easy cleaning.
5.The single level optimization of auto cascade refrigeration system design, keep fast cooling speed and energy saving.
Safety
1.Visual and audible alarm system: High/low temperature, sensor error.
2.Power failure protection: turn on delay of the cooling system when power failure, restart delay protection.
3.Keyboard lock, password protection to avoid set parameter randomly.
4.Special noise reduction design.
5.100mm insulation layer keep perfect performance.Humanized design
1.4 casters with stopper for easy moving and fixation.
2.Standard 25mm test hole for easy connecting to temperature monitoring systems.
3.Safety door lock design ,open the door to prevent abnormal.
4.Large screen digital display for easy observation.Specifications
Model ULF86-H110 ULF86-H490 Specifications Shelf/drawer QTY / / Cooling Direct cooling Direct cooling Defrost Manual Manual Refrigerant R4001 R4001 Power consumption(kWh/24h) 4.79 13.5 Noise(db) 50 54.5 Ambient temperature(℃) 10~32℃ 10~32℃ Temperature range(℃) -40~-86℃ -40~-86℃ Cooling system Compressor brand/QTY CUBIGEL/1 SECOP/1 Sensor PTC PTC Temperature controller Microprocessor Microprocessor Display Digital display Digital display Power Voltage/frequency(V/Hz) 220/50Hz 220/50Hz Power(W) 500W 670W Current(A) 2.53A 3.16A Material Inside material Stainless steel Stainless steel Outside material Color sprayed steel Color sprayed steel Insulation PURF PURF Size Capacity(L/cu.ft) 105/3.70 485/17.12 NW./GW.(kg) 65/70 130/150 Exterior size(W×D×H)(mm) 680*580*935 1695×840×962 Interior size(W×D×H)(mm) 480*380*665 1455.5*525.2*674 Package size(W×D×H)(mm) 770*705*1090 1765×900×1060 CBM 0.59 1.75 20GP/40GP/40HQ 24/51/51 6/13/13 Frozen Racks Racks 4(11X1,6X1) 30(11X1,6X1) Boxes (2 Inches) 34 300 Samples(2ml) 3400 30000 Alarm High/low temperature Y Y Power failure / / Abnormal voltage / / Sensor error Y Y Filter screen check / / Thermostat failure Y Y Low battery / / Condenser clean / / High ambient temperature / / Door ajar / / Power failure backup system(alarm) 12h 12h Accessories Castor Y Y Inside door / / Test hole QTY/diameter 1/25MM 1/25MM USB port / / Chart recorder / / Data logger / / Remote alarm port / / Optional CO2 back up system / / LN2 back up system / / -
商品Q&A