商品資訊
Description
1, High configuration of hardware: 7 inches TFT Color Capacitive Touch-screen Display; Bluetooth 2.1; Concave Grating.
2, Double Array 256 Image Element CMOS Sensor; Long life-span stable xenon lamp.
3, With reflective and transmissive spectrum, accurate Lab value, good to calculate color formula and do precise color transmission.
4, Auto identify measuring aperture. Freely switchable between 3 measuring apertures: Φ 25.4mm/8mm/4mm. Users also can customize apertures.
5, Built-in temperature sensor to monitor and compensate the measuring temperature to ensure the measurement more precision.
6, Wavelength range 360nm – 780nm. Built-in 400nm cut off, more professional in UV measurement.
7, Independent light source detector, continuously monitor the condition of light sources to ensure the light source reliable.
8, Multiple measurement modes: Quality Management Mode, Sample Mode; Meet more users’ requirement.
9,A variety of optional accessories: Reflection sample holding tool, transmission fixture, micro 4mm aperture transmission test components, instrument inversion test components, applicable to more working conditions.
10, Big capacity data storage, for 20000 pieces test result.
11, Built-in camera locating.
12, More powerful extended functions at the PC software.
Application Industry
SP-CLR602 benchtop spectrophotometer is used to do precise color analysis and transmission in laboratories. It can be widely applied in different industries, such as plastics, electronics, paint and ink, printing, garments, leather, paper, auto, medical, cosmetics, food, science institutes, laboratories.
Specifications
Model SP-CLR602(Pulsed xenon lamp) Optical Geometry Reflect: di:8°, de:8°(diffused illumination, 8-degree viewing angle); SCI (specular component included)/SCE (specular component excluded);Include UV / excluded UV light source; Transmittance: di:0°, de:0° (diffuse illumination: 0° viewing); SCI (specular component included)/SCE (specular component excluded);Include UV / excluded UV light source; Haze(ASTM D1003); Conforms to CIE No.15,GB/T 3978,GB 2893,GB/T 18833, ISO7724/1, ASTM E1164, DIN5033 Teil7 Integrating Sphere Size Φ 154mm Light Source Device 360nm-780nm Xenon Lamp, 400nm cut-off Xenon Lamp Spectrophotometric Mode Concave Grating Sensor 256 Image Element Double Array CMOS Image Sensor Wavelength Range 360-780nm Wavelength Pitch 10nm Semiband Width 5nm Reflectance Range 0~200% Measuring Aperture Reflective: Φ30mm/Φ25.4mm, Φ10mm/Φ8mm, Φ6mm/Φ4mm; Transmissive: Φ30mm/Φ25.4mm; Remark: 1. Automatic identification of switch caliber 2. Customized Configuration caliber and lens position Specular Component Reflectance: SCI&SCE Transmittance: SCI&SCE Color Space CIE Lab, XYZ, Yxy, LCh, CIE LUV, Hunter LAB, Munsell, s-RGB, HunterLab, DIN, βxy Color Difference Formula ΔE*ab, ΔE*uv, ΔE*94, ΔE*cmc(2:1), ΔE*cmc(1:1), ΔE*00v, ΔE(Hunter), DIN ΔE99 Colorimetric Index WI (ASTM E313, CIE/ISO, AATCC, Hunter), YI (ASTM D1925, ASTM 313), MI (Metamerism Index), Staining Fastness, Color Fastness, Color Strength, Opacity, Gardner Index, Pt-Co Index, 555 Index, Haze(ASTM D1003),Saybolt Observer Angle 2° & 10° Illuminants D65,A,C,D50,D55,D75,F1,F2,F3,F4,F5,F6,F7,F8,F9,F10,F11,F12,CWF,DLF,TL83,TL84,TPL5,U30 Displayed Data Spectrogram/Values, Chromaticity Values, Color Difference Values/Graph, Pass/Fail Result, Color Offset Measuring Time About 2.4s (Measure SCI & SCE about 5s) Repeatability Spectral reflectance: Φ25.4mm/SCI, Standard deviation within 0.07% (400 nm to 700 nm: within 0.06%) Chromaticity value: Φ25.4mm/SCI, Standard deviation within ΔE*ab 0.015 (When a white calibration plate is measured 30 times at 5 second intervals after white calibration) Spectral Transmittance: Φ25.4mm/SCI, Standard deviation within 0.07% (400 nm to 700 nm: within 0.07%) Chromaticity value: Φ25.4mm/SCI, Standard deviation within ΔE*ab 0.018 (When a white calibration plate is measured 30 times at 5 second intervals after white calibration) Inter-instrument Error Φ25.4mm/SCI, Within ΔE*ab 0.15 (Average for 12 BCRA Series II color tiles) Size 370×300×200mm Weight About 9.6kg Power Supply DC 24V, 3A Power Adapter Light Source Device Life 5 years, more than 3 million times measurements. Display 7″ TFT Capacitive Screen-touch Display Data Port USB & Print serial port Data Storage Standard 2000 Pcs, Sample 20000 Pcs Language Simplified Chinese, Traditional Chinese, English, Working Environment Temperature: 0~40℃; Humidity: 0~85% (No Condensation) Storage Environment Temperature: -20~50℃; Humidity: 0~85% (No Condensation) Standard Accessory Power Adapter,Guide, CD Disk(PC Software), USB cable, Standard Calibration Board, Black Calibration Cavity, Transmission black baffle, Sample holder, 25.4 caliber, 8 caliber, 4 caliber, Optional Accessory Micro-printer, Transmissive Test Clamp Component,Micro Aperture(4mm) transmission test clamp component, Instrument inversion components,culture dish Notes: The specifications are subject to change without notice. -