- 微生物專用設備
- 細胞專用設備
- 基礎理化設備
- 溶液處理移液設備
- 蛋白質專用設備
- Cellpro
- 試劑類
- 培養基類
- 實驗室耗材類
- 儀器維修&校正服務
- 防疫專區
- infitek系列
- pakgent系列
- 塑膠耗材類別
- 冷藏冰箱
-
商品資訊
Description
Automatic microplate reader is a professional instrument for reading and analyzing the results of enzyme-linked immunoassay (EIA) experiments.This product is widely used in applied research in biology, agricultural science, food and environmental science.
This product has the following features:
- Adopt 7-inch high-resolution LCD capacitive touch screen, no keyboard required, simple and intuitive operation, easy to use.
- 8-bit filter wheel, with 4 filters as standard; Other filters are optional; The wavelength range is 340-750nm, which can meet various applications;
- 9-channel vertical light path; Automatic positioning function of the center of the enzyme labeling hole.
- It has the function of single wavelength and dual wavelength detection, and the plate reading is fast; it only takes 10 seconds to read the entire 96-well plate or 16 seconds to complete the dual wavelength detection.
- The built-in software can realize the detection of kinetics, standard curve, qualitative and quality control; The software includes program generation and storage, as well as detection data storage functions, with large storage capacity; it also has powerful curve fitting, kinetic analysis and reporting functions.
- It has the functions of self-checking and diagnosing the optical path, moving position, etc.
- It has the function of vibrating plate, and the vibrating plate time and speed are adjustable.
- The energy-saving design of the light source maximizes the service life of the light source.
- A variety of data output interfaces are available to facilitate data transmission and processing.
- Measurement data can be directly exported to Excel for further analysis.
Specifications
Model MPR-A9600/MPR-A9600T Light source 6V 10W halogen lamp Wavelength range 340~750nm Filter Standard configuration: 405, 450, 492, 630nm four filters;It can be loaded with up to eight filters Absorbance range 0.000-4.000Abs Resolution 0.001Abs Linearity (0, 2.0)≤±1%;[2.0, 4.0)≤±2% Wavelength indication error ≤±3nm Wavelength repeatability ≤±1.5nm Repeatability [0, 3.0)≤0.3%, [3, 4.0)≤1% Stability [0, 3.0)≤0.3%,[3.0, 4.0)≤1% Accuracy [0, 2.0)≤ ± 0.005, [2.0 ,3.0)≤ ± 1%, [3.0, 4.0)≤ ± 1.5% Sensitivity Sensitivity≥0.010 Channel difference <0.01A(1.0Abs standard filter ) Measuring speed Single wavelength <10s/96 wells, dual wavelengths <16s/96 wells (normal mode) Incubation temperature Room temperature+4℃-50℃(MPR-A9600T) External dimensions(W×D×H) 280x432x220 mm(W×D×H) Net weight (kg) 10 Ambient temperature 4℃~ 45℃ Relative humidity ≤70% Power supply VAC 100-240V -